TBII TBII
Sign In Register
Navigation
Home My Cart Shop
Language
🇨🇦 English 🇫🇷 Français 🇪🇸 Español 🇩🇪 Deutsch 🇨🇳 中文 (简体) 🇯🇵 日本語 🇰🇷 한국어
Help
Contact FAQ
© 2026 TBII. All rights reserved.
Best-Selling New In

PH Meter 0.01 High Precision for Water Quality Tester with 0-14 Measurement Range Suitable Aquarium Swimming Pool

$12.19 Reference price: $67.12 Save 82%
Qty:

  • Fast delivery
  • 30-day returns
Ships to Canada · Delivery Approximately 7 days (supplier estimate)
Sold by TBII
Category DIY, Tools & Hardware › Tools & Equipment › Measuring Tools In stock Ships to Canada Estimated Delivery Approximately 7 days (supplier estimate)

PH Meter 0.01 PH High Precision Water Quality Tester with 0-14 PH Measurement Range, Suitable for Aquarium, Swimming Pool, Indoor Outdoor

Digital PH Meter Water Tester

The product has been calibrated before leaving the factory, and can be used directly after receiving the package, and then calibrated according to the situation

It's not only ideal for household or laboratory use, also suitable for testing pH balance of drinking water, pool, aquarium, food Project, RO system, Spa, or hydroponics.

Specifications:

► Measuring range: 0.00-14.00 pH

► Resolution: 0.01 pH

► Accuracy: 0.01 pH

► Batteries: 2X 1.5V LR44 (included)

► Automatic temperature compensation: 0-50Centigrade(32-122It)

► Dimensions: 15x2.5x1.3cm/6x1.1x0.5 inch

► Net Weight: 52g/1.83 oz

Warm tips

It STEP 1: Turn open pH meter, Clean the electrode in distill water

It STEP 2: Immerse the electrode in pH 6.86 standard buffer solution

It STEP 3: Press the "CAL" button. Wait until the display digital is 6.86pH and steady

It STEP 4: Clean the electrode in distill water and dry it, immerse the electrode in Ph 4.00 standard buffer solution

It STEP 5: Press the "CAL" button. Wait until the display digital is 4.00pH. Then complete pH 4.00 calibration

It STEP 6: Clean electrode and dry it, put the meter into PH 9.18 standard buffer solution. Check if reading is correct between 9.17-9.19pH

Instructions for use of PH calibration powder:

Calibration powder: pH standard solid substance. It can be used after adding water. Suitable for the calibration of any type of ph meter. Each package can prepare 250ML standard solution.

(Be sure to add water according to the required ratio, otherwise it will affect the accuracy of the calibration and increase the error)

Precautions:

Please note that the PH pen probe is a glass product and is a fragile product. Please do not collide with things. Once the damage is not replaceable, you must protect the probe. After use, use absorbent paper to gently absorb the water on the probe.

Matters needing attention:

PH meter has been calibrated before delivery, the buyer does not need to re-calibrate after receiving the goods!

In the following cases, the PH meter must be re-calibrated:

1. Has been used for a long time after calibration;

2. Special electrode use Frequently;

3. The measurement accuracy requirements are relatively high.

Standard configuration:

1XPH meter with opp bag

2X LR44 Button batteries

1X instruction manual

Questions & Answers:

1. Q: How often should I calibrate my ph meter pen ?

A: One calibration can last for about half a month. When the electrode exposed to air for extended period of time, users should calibrate it. When testing polluted water quality, more frequent calibration is required to ensure the accuracy of the test value

2. Q: Can I test two kinds of water without calibrating ?

A : Yes , but when testing the liquid that is not pure water or distilled water, after the test, you need to put it in pure water or distilled water, wash it and wipe it dry, and then test the next liquid (to ensure the accuracy of the value of the next test liquid)

3. Q: Why my ph meter switch and digital display are not sensitive ?

A: It might be caused by low battery. Just replace the battery and it will work again.

4. Q: Can I use this to test Urine ?

A: Yes , it can. The test liquid must not be corrosive, which will damage the accuracy of the glass probe and shorten the service life of the glass probe.

5. Q: What if the calibration result is wrong?

A: Assuming that the calibration result is wrong, the pen recognizes ph 9.18 or ph 4.01 after calibrating ph 6.86 .

Step 1: Take 50ml of purified water or distilled water, and then import one pack of 6.86 calibration powder, stir evenly, put the PH pen probe in water for One Hours.

Step 2: Then turn on the pen, press and hold the CAL button for five seconds, then let go, the value flashes, and the END calibration is completed.

Except the ways above, you could long press the switch and calibration keys at the same time for five seconds, restore the factory settings, and then test.

( The test difference might within 2% with reset control , and the powder calibration's test difference is within 0.1%-1% )


CategoryDIY, Tools & Hardware › Tools & Equipment › Measuring Tools
Availability In stock
Ships toCanada
Buyer Guarantees15-Day No Update Refund & 60-Day No Delivery Refund

No reviews yet

Be the first to share what you think of this product.

Fast Delivery Nationwide shipping
Best Price Guarantee We'll match any price
Easy 30-Day Returns No questions asked
Secure Checkout 256-bit SSL encrypted